Description:
The level electrodes NRG 1...-50 are used in conjunction with level switch NRS 1-50 as water level limiters for steam boiler plants and (pressurised) hot water installations. Water level limiters switch off the heating when the water level falls below the set minimum level (low water).
Function
When the water level falls below the low level, the level electrode is exposed and a low level alarm is triggered in the level switch NRS 1-50. This switchpoint “Low water level (LW)” is determined by the length of the electrode tip. The electrode operation is based on the conductive measuring principle using the electrical conductivity of the water for signalling water level. The self-monitoring function ensures that an alarm will also be triggered if the electrode insulation is contaminated or has developed a leak and/or if there is a malfunction in the electrical connection. The level electrode is installed inside steam boilers, vessels or inlet lines of hot-water systems. The protection tube provided on site ensures the function. One level electrode NRS 1...-50 can be installed together with one GESTRA level electrode, one level switch or transmitter for water level control and high level alarm in one single protection tube or level pot. If the level electrode is installed in a level pot outside the boiler, make sure that the connecting lines are rinsed regularly. In addition, the logic unit SRL is required to monitor the purging times and the purging sequence. If the connecting lines for steam ≥ 40 mm and water ≥ 100 mm the installation is considered as “inside”. In this case the purging process does not have to be monitored.
Service pressure
Connection
Materials
Lengths supplied
Gestra Water Level Limiter NRG 16-50 NRG 17-50, NRG 19-50 NRG 111-50
-
Popular Tags :
Gestra Water Level Limiter NRG 16_50 NRG 17_50, NRG 19_50 NRG 111_50 | Aquametro | Ari Armaturen | Asahi | Beru | Bonney Forge | Condor | Danfoss |
Other product from brand
Gestra Check Valve Circulation Check PN 6
Gestra Thermostatic Steam Trap BK 15 ANSI 300
Gestra Thermodynamic Steam Traps DK | Steam Equipment
Gestra Drainage Module QuickEM
Gestra Pressure Reducing Valve Type 5801
Gestra NRGS 11_2 NRGS 16_2
Gestra Pressure Reducing Valve
Gestra vaposcope vk 14 vk 16
Gestra Level Switches
Gestra NRGS 11_1 NRGS 16_1 NRGS 16_1S
Gestra Steam Trap BK 46 PN 40 DN 15 20 25
Sparepart Boiler Gestra Blowdown Valve
Gestra Cooling Water Control Valves CW 44 Pressure Reducing
Gestra Simple Cooler PK 40
Gestra Ball Float Steam Traps | Steam Equipment
Related Products
IFM LEVEL SENSOR PI2798
Igema Reflex Level Gauges
Mobrey Magnetic Level Switches
Gestra Level Switches
Yoshitake Expansion Joint EB 1J EB 2J series JIS 10K
IFM LEVEL SENSOR LMC100
Mobrey magnetic horizontal level switch
Water Level Boiler Reflex Gauge
IFM Encoders
Igema Magnetic Level Gauges
IFM LEVEL SENSOR LMT102
IFM LEVEL SENSOR LR2050
IFM LEVEL SENSOR PI2797
McDonnell & Miller Low Water Cut Offs Pump Controllers
Gestra Level Electrodes NRG
IFM LEVEL SENSOR LMT100
Gestra Water Level Limiter NRG 16_50 NRG 17_50, NRG 19_50 NRG 111_50
IFM LEVEL SENSOR LMT110
IFM LEVEL SENSOR LMT104