INSTALLATION
The installation of the pressure regulator must occur in compliance with the provisions (laws or regulations) in force in the place of installation. In detail, natural gas plants must show features complying with the law provisions or regulations in force in the place of installation or at least complying with the standards EN 12186 or EN 12279. The installation in compliance with such standards minimizes the risk of fire and the formation of potentially hazardous atmospheres. The equipment is not provided with internal pressure limitation devices; therefore, it must be installed making sure that the operating pressure of the installation in which it is installed does not exceed the value of the allowable maximum pressure (PS). The user shall therefore, when he/she deems it necessary, provide for the installation on the assembly of suitable pressure limitation systems; Moreover, the user shall equip the plant with suitable relief or drain systems in order to be able to discharge the pressure and the fluid contained in the plant before proceeding with any inspection and maintenance activity. Should the installation of the equipment require the installation on site of compression fittings, these latter have to be installed following the instructions provided by the manufacturer of the fittings. The selection of the fittings must be compatible with the use specified for the equipment and with the plant specifications, when foreseen.
The pressure regulator DIVAL 500 is a pressure regulator for previously cleaned gaseous fluids, suitable for low, medium and high pressure. DIVAL 500 is a normally open regulator and, therefore, it opens in case of:
- breakage of the main membrane;
- lack of regulated pressure signal. The main features of this regulator are:
13 ÷ 100 mbar for BP head;
100 ÷ 300 mbar for MP head;
300 ÷ 2500 mbar for TR head;
Dival 500 Gas Pressure Regulator
Accuracy class: up to 10 Available size DN: 1″ x 1″, 1″ x 1″ 1/2 Closing pressure class SG: up to 10 Design pressure: up to 10 bar for BP, up to 20 bar for MP and TR Design temperature: from -20 °C to +60 °C Minimum working differential pressure: 0.1 bar Outlet pressure range of Wd: from 13 to 100 mbar for BP, from 100 to 300 mbar for MP, from 300 to 2500 mbar for TR Range of inlet pressure bpu: from 0.5 to 10 bar for BP, from 0.5 to 20 bar for MP and TR
Popular Tags :
Dival 500 Gas Pressure Regulator | Aquametro | Ari Armaturen | Asahi | Badger Meter | Beru | Condor | Danfoss |
Other product from brand
Dival 500 Gas Pressure Regulator
Dival 160 AP Gas Pressure Regulator
Apperflux 851 gas pressure regulator
Staflux 185 High Medium Pressure Gas Regulator
DIVAL 600G MP Dival 600 Series
asx 176 high medium gas pressure regulator
Apperflux 101 gas pressure regulator
Related Products
Giuliani Anello Air Gas Ratio Control Valve GAVR 20
Dungs Single stage safety solenoid valves
Honeywell Gas Pressure Regulator
Anello Solenoid Valves
Seitron Gas Detectors Gas Analyzer and Detector
Dungs GasMultiBloc
Anello Anti Vibration Joint
Anello Gas Pressure Regulators
Italpump Gas Pressure Regulators
Honneywell Gas Pressure Regulator MK2 DN 50 PN 16
DIVAL 600G MP Dival 600 Series
Geca Gas Filter GF 1/2inc 3/4inc 1inc
Anello Gas Filters
Dungs Gas Regulator FRS 520
Dungs Ratio Regulator and Zero Governor
Giuliani anello AIR GAS RATIO CONTROL VALVES GAVR 15
Giuliani Anello Air Gas Ratio Control Valve GAVR 25
Siemens Gas valve Actuator SKP55
Giuliani anello Air And Gas Filter 70600
Seitron Gas Analyzer Chemist 100